500-173 Sample Questions & Answers
Sizing FlexPod components to customer workloads carries the top weight, alongside secure multitenancy design, troubleshooting resources, configuring UCS for compute, protecting data through NetApp storage protocols, and FlexPod networking choices.
Launch the full 500-173 simulator →Free 500-173 Sample Questions with Answers
Real questions from the Designing the FlexPod Solution (FPDESIGN) practice test — answers and explanations included. Showing 10 of 20 free samples.
- Question 1Intermediate
Networking · Demonstrate knowledge of FlexPod networking configurations
A network engineer is configuring a FlexPod that uses Nexus 9000 series switches for data networking. To provide a redundant, loop-free Layer 2 topology between the Nexus switches and the Cisco UCS Fabric Interconnects, which technology is the recommended best practice?
Show answer & explanation
Correct answer: B
Virtual Port Channel (vPC) is the standard and recommended technology for connecting UCS Fabric Interconnects to upstream Nexus switches. vPC allows links that are physically connected to two different Nexus switches to appear as a single PortChannel to the Fabric Interconnects. This provides active-active forwarding paths, full link utilization, and a loop-free topology without relying on Spanning Tree Protocol to block links.
- Question 2Advanced
Security · Describe the considerations in building a secure multitenancy design
A cloud provider is building a secure multi-tenant FlexPod environment. They need to provide complete network and storage isolation for each tenant. Which combination of technologies is required to achieve this at both the storage and network layers?
Show answer & explanation
Correct answer: C
This is the most comprehensive solution for multi-tenancy. NetApp Storage Virtual Machines (SVMs) provide logical isolation of data and administration. IPspaces further isolate networking within the SVM, preventing IP address overlap. On the networking side, VLANs are used to segment Layer 2 traffic for each tenant, and VSANs are used to create separate, isolated Fibre Channel fabrics for SAN traffic, ensuring complete tenant separation across all layers.
- Question 3Intermediate
Tools · Demonstrate knowledge of using tools for managing FlexPod
An administrator is using Cisco UCS Director to automate the provisioning of a new virtual machine on a FlexPod. Which of the following best describes the primary role of UCS Director in this context?
Show answer & explanation
Correct answer: C
Cisco UCS Director (now part of Cisco Intersight) is a multi-domain orchestration platform. Its primary function is to automate and orchestrate workflows that span across the different components of a converged infrastructure like FlexPod. When provisioning a VM, it can automatically create the UCS service profile, configure the network VLANs on the Nexus switch, provision the storage LUN or volume on the NetApp array, and deploy the VM onto the hypervisor, all from a single workflow.
- Question 4Intermediate
Compute · Describe the Cisco UCS components used within FlexPod designs
A systems engineer is tasked with designing a compute environment for a new FlexPod that will host a large-scale Oracle RAC database. The customer requires high compute density and the ability to scale compute resources independently of the chassis. Which Cisco UCS server series is the most appropriate choice for this design?
Show answer & explanation
Correct answer: B
Cisco UCS C-Series Rack Servers are ideal for scale-out workloads like Oracle RAC. They provide powerful standalone compute that can be managed by UCS Fabric Interconnects. C-Series servers offer more options for local storage and GPU expansion compared to blades and can be added to the rack one at a time, providing granular scalability. B-Series are excellent for density but are tied to chassis slots. S-Series is for storage, and E-Series is for edge computing.
- Question 5Beginner
Compute · Demonstrate knowledge of how to configure the logical components used in a UCS server
In a FlexPod design, what is the primary purpose of creating a service profile template within Cisco UCS Manager?
Show answer & explanation
Correct answer: B
A service profile template acts as a blueprint for creating service profiles. Its primary purpose is to ensure that multiple servers are configured identically and consistently. By defining policies for firmware, boot order, network (vNICs), and storage (vHBAs) in a template, an administrator can quickly instantiate multiple service profiles that adhere to a standard, reducing manual errors and simplifying management.
- Question 6Intermediate
Storage · Describe storage protocol considerations in FlexPod designs
A designer is planning the storage protocols for a new FlexPod that will serve a large VMware vSphere environment. The design goals are high performance, low CPU overhead on the hosts, and dedicated, isolated paths for storage traffic. Which storage protocol should be recommended?
Show answer & explanation
Correct answer: C
Fibre Channel (FC) is the ideal choice for these requirements. It operates over a dedicated, lossless network (the SAN fabric), providing traffic isolation. It uses specialized Host Bus Adapters (HBAs) in the servers, which offload the protocol processing from the CPU, resulting in lower host overhead compared to software iSCSI. This combination delivers high, predictable performance suitable for demanding VMware environments.
- Question 7Beginner
Storage · Demonstrate knowledge of the features required for data protection or backup for FlexPod design
Which NetApp feature provides space-efficient, instantaneous, point-in-time copies of data volumes or LUNs, which can be used for rapid backup and recovery operations within a FlexPod environment?
Show answer & explanation
Correct answer: B
NetApp Snapshot technology creates point-in-time copies of data by manipulating block pointers in the WAFL (Write Anywhere File Layout) file system. This process is nearly instantaneous and highly space-efficient because it only stores changed blocks, not a full copy of the data. Snapshots are the foundation of NetApp's data protection and are heavily used for backup, restore, and cloning operations.
- Question 8Advanced
Networking · Demonstrate knowledge of FlexPod networking configurations
Case Study
A mid-sized e-commerce company, "ShopFast," is experiencing rapid growth and needs to overhaul its aging infrastructure. Their current environment consists of disparate servers and storage arrays, leading to management complexity, unpredictable performance during peak sales events, and lengthy provisioning times for new services. They have decided to migrate to a FlexPod Datacenter solution to standardize their platform and improve agility.
The core requirements for the new design are: support for 500 VMware virtual machines running a mix of web front-ends, application servers, and several Microsoft SQL Server databases; the ability to scale compute and storage independently to meet future growth; a highly resilient network design that can survive a single switch failure without packet loss; and streamlined management for the entire stack.
The design team has proposed using Cisco UCS B200 M6 blades in a UCS 5108 chassis, managed by a pair of UCS 6454 Fabric Interconnects. For storage, a NetApp AFF A250 cluster is selected. For networking, a pair of Cisco Nexus 93180YC-EX switches will be used. The business has also stipulated that the design must follow the latest Cisco Validated Design (CVD) for VMware on FlexPod.
Given this scenario, which networking configuration between the UCS Fabric Interconnects and the Nexus 93180YC-EX switches is essential to meet the high-resiliency requirement specified by ShopFast?
Show answer & explanation
Correct answer: C
To meet the high-resiliency requirement of surviving a single switch failure without packet loss, a Virtual Port Channel (vPC) is the correct design. The two Nexus switches are configured in a vPC domain, and the UCS Fabric Interconnects are connected via a port-channel that spans both physical switches. This creates a single logical uplink from the UCS domain, providing active-active forwarding, full bandwidth utilization, and seamless failover if one of the Nexus switches fails. This is the standard best practice in FlexPod CVDs.
- Question 9Beginner
Security · Describe access control methods for FlexPod solutions
A FlexPod solution requires centralized authentication for administrative access to Cisco UCS Manager, Nexus switches, and NetApp ONTAP. The corporate security policy mandates the use of Microsoft Active Directory for user credentials. Which access control method should be implemented on all components?
Show answer & explanation
Correct answer: D
Microsoft Active Directory is a directory service that uses the Lightweight Directory Access Protocol (LDAP) for querying and modifying data. All major FlexPod components—Cisco UCS Manager, Cisco NX-OS, and NetApp ONTAP—support integration with Active Directory via LDAP for authentication and authorization. This allows administrators to use their corporate AD credentials to log in, providing centralized user management and policy enforcement.
- Question 10Beginner
Compute · Describe the Cisco UCS components used within FlexPod designs
During the design phase of a FlexPod, a question arises about the maximum number of Cisco UCS B-Series blades that can be installed in a single chassis. Which UCS component directly determines this maximum physical capacity?
Show answer & explanation
Correct answer: B
The Cisco UCS 5108 Chassis is the physical enclosure that houses the B-Series blade servers. It has a fixed number of slots. The standard 5108 chassis provides eight half-width slots or four full-width slots (or a mix). Therefore, the chassis model itself dictates the maximum number of blades that can be physically installed.
Ready for the real thing?
The full 500-173 simulator has every exam-style question, timed mode, and instant scoring.