NS0-520 Sample Questions

NS0-520 Sample Questions & Answers

Node configuration, SVM setup and FCP, NVMe or iSCSI work make up the biggest share, alongside switch and controller setup alongside data protection, hardware provisioning plus configuration tools and component prerequisites, and testing, troubleshooting and migration.

Launch the full NS0-520 simulator →

Free NS0-520 Sample Questions with Answers

Real questions from the Netapp Certified Implementation Engineer - San Ontap practice test — answers and explanations included. Showing 10 of 20 free samples.

  1. Question 1Intermediate

    ONTAP SAN Concepts · Storage Space Utilization and Management

    An administrator is provisioning a new 5 TB LUN for a VMware datastore. To optimize space savings, they want to use thin provisioning and enable deduplication. What is the correct sequence of operations in ONTAP?

    Show answer & explanation

    Correct answer: C

    Storage efficiency features like deduplication and compression are enabled at the FlexVol volume level, not on individual LUNs. To achieve the goal, the administrator must first ensure deduplication is enabled on the volume that will contain the LUN. Then, the LUN should be created with space reservation disabled (-space-reserve disabled), which is how thin provisioning is implemented for a LUN in ONTAP.

  2. Question 2Intermediate

    ONTAP SAN Implementation Testing and Troubleshooting · Troubleshooting Procedures

    An administrator is investigating a performance issue where a Linux host connected via FC is experiencing intermittent high latency. The ONTAP cluster has four nodes. The administrator suspects the host is sending I/O over non-optimal paths. Which ONTAP CLI command would help verify the LUN's logical path and its physical location?

    Show answer & explanation

    Correct answer: B

    The lun show command with the -fields node parameter is the most direct way to identify which node currently owns the volume containing the LUN. This information is crucial for determining the optimal I/O paths. If the host is primarily using LIFs on a different node, it indicates a pathing issue that would cause higher latency due to cluster interconnect traffic.

  3. Question 3Advanced

    ONTAP SAN Implementation Testing and Troubleshooting · Troubleshooting Procedures

    A new iSCSI LIF is created on an ONTAP node, but the host initiator is unable to log in to the target portal. A packet capture on the host shows it is sending discovery requests, but no response is received from the storage. The LIF can be pinged from the host. What is the most likely cause of this issue?

    Show answer & explanation

    Correct answer: C

    Since the LIF is reachable via ping (ICMP), basic network connectivity is confirmed. However, the lack of response to iSCSI discovery requests (typically on TCP port 3260) points to a higher-level block. In ONTAP, each LIF has an associated firewall policy. If this policy does not explicitly allow the 'iscsi' service, the node will drop the incoming discovery packets, leading to this exact symptom.

  4. Question 4Intermediate

    ONTAP SAN Implementation Testing and Troubleshooting · Data Migration

    A new SAN implementation requires migrating LUNs from a third-party storage array to a new ONTAP cluster with minimal host-side disruption. The implementation engineer plans to use Foreign LUN Import (FLI). Which step is essential for the cutover phase of the FLI process?

    Show answer & explanation

    Correct answer: B

    The cutover for FLI requires a brief outage. The correct procedure involves shutting down the application/host, removing the zoning for the old storage array paths, creating new zones for the ONTAP paths, and then bringing the host back up. Once online, a rescan of the storage bus will discover the LUNs presented from the ONTAP system, completing the migration.

  5. Question 5Beginner

    ONTAP SAN Implementation and Configuration · FCP, NVMe, and iSCSI Configuration

    What is the primary function of a portset in an ONTAP FCP environment?

    Show answer & explanation

    Correct answer: C

    A portset is a mechanism used to control which FCP target LIFs are visible to a specific initiator group (igroup). By binding an igroup to a portset, you limit the paths that the initiators in that group can use to access LUNs. This is often used to enforce specific pathing policies or to isolate traffic in multi-tenant environments.

  6. Question 6Intermediate

    ONTAP SAN Implementation and Configuration · FCP, NVMe, and iSCSI Configuration

    You are configuring a new SVM for iSCSI access on a 2-node AFF A250 cluster. To ensure high availability and load balancing, what is the minimum number of iSCSI data LIFs that should be created for this SVM?

    Show answer & explanation

    Correct answer: B

    NetApp best practice for iSCSI is to configure a minimum of two data LIFs per node for each SVM providing SAN access. This configuration provides path redundancy across the node's network ports and allows for better load balancing by the host's multipathing software. For a 2-node cluster, this results in a total of four LIFs for the SVM.

  7. Question 7Intermediate

    ONTAP SAN Implementation and Configuration · FCP, NVMe, and iSCSI Configuration

    When implementing NVMe/FC on an existing FC SAN fabric, which switch-level feature is a mandatory prerequisite for ONTAP integration?

    Show answer & explanation

    Correct answer: B

    NPIV is a fundamental requirement for both FCP and NVMe/FC in a virtualized storage environment like ONTAP. It allows a single physical Fibre Channel port (N_Port) to register multiple unique World Wide Port Names (WWPNs) with the fabric. ONTAP uses this feature to assign unique WWPNs to each FCP and NVMe/FC LIF, which is essential for proper zoning and host recognition.

  8. Question 8IntermediateSelect 3

    ONTAP SAN Implementation and Configuration · Switches and Host Systems Configuration

    A new Linux host with a QLogic HBA needs to be connected to an ONTAP cluster via FC. After zoning is completed on the switch, which three steps must be performed to provision a LUN to the host? (Select THREE)

    Show answer & explanation

    Correct answers: A, B, C

    The first step is to create the LUN itself within an existing or new volume on the SVM.

    An initiator group (igroup) must be created to represent the host. The World Wide Port Names (WWPNs) of the host's HBAs are added to this igroup.

    Finally, a LUN map is created. This map links the specific LUN to the igroup, which makes the LUN visible to the host initiators defined in that igroup.

  9. Question 9Advanced

    ONTAP SAN Solution Assessment · Solution Design and Hardware Provisioning

    You are a consultant tasked with designing a SAN solution for a new ONTAP deployment. The customer has a mix of high-performance database workloads and general-purpose virtual machines. They have provided the following requirements:

    • Databases: Must have the absolute lowest latency. The application vendor requires dedicated physical infrastructure.
    • Virtual Machines: Should leverage existing 10GbE network infrastructure to minimize costs.
    • Management: Must be able to manage both environments from a single ONTAP cluster.

    Which design would you propose to meet all customer requirements?

    Show answer & explanation

    Correct answer: C

    This design meets all requirements. Using NVMe/FC provides the lowest possible latency for the critical databases on dedicated infrastructure. A separate SVM for iSCSI leverages the existing 10GbE network for the VMs, minimizing cost. The use of two SVMs provides logical isolation between the workloads while still allowing them to be managed from a single ONTAP cluster, fulfilling all constraints.

  10. Question 10Beginner

    ONTAP SAN Solution Assessment · Environmental and Physical Considerations

    A customer is planning a SAN deployment in a new data center that has strict power and cooling limitations. As part of the solution assessment, you need to provide accurate environmental specifications for a proposed 4-node FAS8700 cluster with five DS224C shelves. Which NetApp tool is designed to calculate these power, cooling, and weight metrics?

    Show answer & explanation

    Correct answer: C

    The NetApp Hardware Universe (HWU) is the definitive tool for obtaining detailed hardware specifications, including environmental data. It allows users to build a virtual configuration with specific controllers, shelves, and adapters, and it will generate a report with the total power consumption (Watts), heat dissipation (BTU/hr), and weight for the entire configuration.

Ready for the real thing?