NS0-522 Sample Questions

NS0-522 Sample Questions & Answers

Four areas split the exam evenly: clustered storage with SVM and FCP configuration, testing, troubleshooting and data migration, prerequisites and inventory for installing SAN components, and data protection with host and storage controller configuration concepts.

Launch the full NS0-522 simulator →

Showing 6 of 12 free samples.

  1. Question 1Intermediate

    ONTAP® SAN solution assessment · Solution design and hardware provisioned to meet customer's requirements or expectations

    A manufacturing company is upgrading its data center and wants to implement a new ONTAP SAN solution. They have the following requirements and constraints:

    • They require ultra-low latency for a new real-time analytics database.
    • They have a limited budget and cannot afford to upgrade their existing 25GbE IP network to Fibre Channel infrastructure.
    • Their existing Linux hosts support modern storage protocols over Ethernet.
    • They want to minimize CPU overhead on the storage controllers.

    Which SAN protocol is the optimal choice for this specific solution design?

    Show answer & explanation

    Correct answer: D

    NVMe/TCP is the optimal choice here. It provides ultra-low latency and lower CPU overhead compared to iSCSI, satisfying the performance requirements. Furthermore, it runs over standard Ethernet (their existing 25GbE network), completely avoiding the high cost of implementing a new Fibre Channel infrastructure which would be required for FCP or NVMe/FC.

  2. Question 2Advanced

    ONTAP® SAN solution assessment · Solution design and hardware provisioned to meet customer's requirements or expectations

    You are designing an active-active SAN architecture for a high-transaction Microsoft SQL Server environment on ONTAP 9.16.1. The customer explicitly requires that I/O can be processed directly by either controller in the HA pair without relying on ALUA non-optimized paths passing through the cluster interconnect.

    Which NetApp storage architecture must be proposed to meet this specific requirement?

    Show answer & explanation

    Correct answer: C

    In ONTAP 9.16.1, an ASA reports FC and iSCSI paths through both controllers as active/optimized, so either node serves I/O directly. AFF and FAS mark the partner's paths non-optimized, and that I/O crosses the cluster interconnect.

  3. Question 3BeginnerSelect 2

    ONTAP® SAN solution assessment · Environmental or physical considerations

    During the site readiness assessment for a new ONTAP HA pair deployment, you need to ensure the data center can accommodate the physical requirements of the new controllers and disk shelves.

    Which two physical/environmental considerations must be verified before installation? (Select TWO)

    Show answer & explanation

    Correct answers: B, C

    Controllers and disk shelves are deep and heavy. Check that the racks are deep enough and rated for the weight before the equipment arrives.

    The site must supply enough power for the new systems and remove the heat they produce. Check power and cooling capacity before installation to avoid overheating or tripped breakers.

  4. Question 4Intermediate

    ONTAP® SAN solution assessment · Solution design and hardware provisioned to meet customer's requirements or expectations

    When designing a Fibre Channel fabric for a new ONTAP SAN environment, what is the NetApp best practice for configuring FC zones?

    Show answer & explanation

    Correct answer: D

    NetApp best practice dictates single-initiator, multiple-target zoning. This means one host initiator (WWPN) per zone, but it can be zoned to multiple storage target ports (WWPNs) within that same zone. This prevents cross-talk between different host initiators while minimizing the total number of zones required.

  5. Question 5Intermediate

    ONTAP® SAN solution assessment · Environmental or physical considerations

    A customer is planning a 4-node AFF cluster for a mixed SAN and NAS workload. During the physical cabling assessment, you notice that the cluster interconnect switches are being shared with the host data network to save on switch ports.

    Why must this design be rejected during the assessment phase?

    Show answer & explanation

    Correct answer: A

    ONTAP nodes talk to each other over a private, dedicated cluster interconnect on supported cluster switches. Host data traffic on those switches can delay cluster traffic, so the design must change.

  6. Question 6Advanced

    ONTAP® SAN solution assessment · Solution design and hardware provisioned to meet customer's requirements or expectations

    You are sizing a new ONTAP AFF system for a peak SAN workload. The customer requires maximum performance with the lowest possible latency for a mission-critical Oracle database.

    When considering storage efficiencies (deduplication and compression) during the sizing assessment, what is the best practice for this specific workload?

    Show answer & explanation

    Correct answer: B

    The best practice for Oracle on ONTAP is to keep the default efficiency features on. Inline adaptive compression has shown no measurable latency cost, even on all-flash systems. It also lowers the capacity you must buy.